SSC 90/600 - Solid State Converter |
Leider liegt für diesen Beitrag keine deutsche Übersetzung vor!
SSC 90/600 Solid State converter changes the industrial frequency 380V
50Hz into 115V/200VAC 400Hz for aircraft use. SSC 90/600 can supply 90 KVA power rating, one 400Hz,115/200V AC output and one 28V 600A DC output.
The flexible design allows the GPU to be setup for either bridge, fixed or trailer mounted. The advanced SV-PWM technology, micro-processor based intelligent control system gives low distortion and good dynamic characteristics.
Norms and standards
- DFS400 Specification for 400Hz aircraft power
- ISO6858 Aircraft ground support electric supplies
- MIL-STD-704 Aircraft electric power characteristics
- SAE ARP 5015 Ground equipment 400Hz ground power
- BS 2G 219 General requirements for ground support electric supplies for aircraft
- EN62040-1-1 General & safety requirement
- EN61558-2-6 General & safety requirement
- EN61000-6-4 Electromagnetic compatibility
Generic emission standard
- MH/T6018-1999 Ground static power supply
- Q/WGT018-2006 WG series ground static and DC static power supply
Features
- Equipped with international class components
- Very low distortion and pollution to the mains power.
- Independent voltage regulation of three phases give larger overload capacity
- Automatic line drop compensation Advanced self-diagnostics
- Complete monitoring, recording and protection of internal and external fault conditions
- Parameters in running conditions, operations records, fault conditions and black-box can be viewed and recalled through user friendly display interface
- Ease of operation and maintenance Protections
- Protection class: IP54
- No break power transfer
- Over/ under Voltage at in/output
- Over/Under Frequency at in/output
- Internal high temperature
- Internal voltage error
- Short circuit at output etc.
Electrical Specifications
Input:
- Voltage range: 3X400V ±15%
- Frequency: 50/60 Hz±5%
- Rectification: 12-pulse
- Line Current Distortion: <10%(distortion free mains voltage) at 100% load
- Power Factor: >0.96 at 100% load
- Inrush Current: None, soft start
- Power interruption: 20 ms
Output:
AC output:
- Power: 90 KVA, cosφ=0.8
- Voltage: 3x115/200V
- Frequency: 400Hz ±0.1%
- Power Factor: 0.7 Lagging to 0.95Leading
- Voltage Regulation: <0.5% for balanced Load up to 30% unbalanced load
- Voltage Transient Recovery: δU<8%, and time<10ms @ 100% load change
- Crest Factor: 1.414 ±3%
- Voltage Modulation: <1.0%
- Phase Angle Symmetry: 120°±1° for balanced Load,
- Phase Angle Symmetry: 120°±2° for 30% unbalanced load
- Total Harmonic Content: <2% at linear load
DC output:
- Voltage: 28V
- Rated current: 600A
Efficiency
- Overall efficiency: >0.93 at 100% load; >0.92 at 50% load,PF:0.8
- Stand By Losses :<50 W
Overload ratings
- 125% 600 seconds
- 150% 60 seconds
- 200% 30 seconds
- 250% 10 seconds
Environmental
- Ambient temperature: -40°C to +55°C
- Relative humidity 10-100%
- Noise level <65 dB(A)@1m
Miscellaneous
- MTBF( proven) :25000 hours
- MTTR: Max. 20minutes
Available standard options:
- Input adaptation
- Additional base module
- Additional output contactor
- Terminal extension for 2 pcs of 7 core cable
Weight and dimensions:

Download:
 Technical information for download
|